** We are
not a seller/supplier of the products below. These instruments are used
for research.**
Barometric Pressure Sensor: CS105
- Measures barometric pressure over 600 to 1060 mb range
- Accuracy is ±0.5 mb @ +20ºC
- Integral mounting bracket optimized for mounting in CS enclosures
- Integral switching circuit allows power consumption only during measurement
cycle
- Manufactured by Vaisala, Inc.
- Power: 5Vdc, 4mA from logger
- Product
Literature (128 kBytes, PDF)
- Manual
(154 kBytes, PDF)
Back to top
Eppley Precision Infrared Radiometer: PIR
The Precision Infrared Radiometer, Pyrgeometer, is intended for unidirectional
operation in the measurement, separately, of incoming or outgoing terrestrial
radiation as distinct from net long-wave flux.
- Sensitivity: approx. 4 µV/Wm-2
- Impedance: approx. 700 Ohms
- Linearity: ±1% from 0 to 700 Wm-2
- Response time: 2 seconds (1/e signal)
- Cosine: better than 5%
- Mechanical Vibration: tested up to 20 g's without damage
- Calibration: blackbody reference
- Size: 5.75 inch diameter, 3.5 inches high
- Weight: 7 pound
- Orientation: Performance is not affected by orientation or tilt
Back to top
Pressure Transducer
Hydrostatic Water Depth & Temperature
Probe: Unidata 6508
The model 6508 Hydrostatic water depth & temperature probe provides
accurate long term measurements of water depth from 0 to 20 metres and water
temperature from -1 to 60°C. They are fully sealed and temperature compensated.
- Resolution: 0.1% of full scale
- Accuracy: ±1% of full scale
- Overpressure: Upto 100% of rated depth
- Sensor: Semiconductor strain gauge element
- Output Signal: Analogue, 0 - 2.55Vdc; 1 for temperature, 1 for depth
- Power: 5Vdc, 4mA from logger
- Size: 25mm diameter, 180mm long
- Weight: 200g (excluding cable)
Back to top
Kipp & Zonen Net Radiometer: CNR1
The Net Radiometer CNR 1 is an ideal instrument for the analysis of Solar
and Far Infrared radiation balance. Includes two pyranometers CM3 ( 0.3
- 3 µm ) for solar radiation measurement (incoming/reflected/albedo/balance).
Includes two pyrgeometers CG3 (5 - 50 µm) for far infrared measurement (balance/soil
surface temperature/sky temperature).
- CM3 range: 305 – 2800 nm; response time: 18 sec; directional
error: < 25 W/m2
- CG3 range: 5000 – 50.000 nm; response time: 18 sec; directional
error: < 25 W/m2
- Operating temperature: -40 – +70 °C
- Expected accuracy for daily: totals ± 10%
- Cable length: 10 m; weight: 4kg
- Required data acquisition - for net radiation: one millivolt channel;
for all four components : four millivolt channels
Back to top
Kipp & Zonen Pyranometer: CM21
The CM21 pyranometer is intended for high accuracy total global, or diffuse
sky, solar radiation measurement research on a plane/level surface, for
extreme temperature environments.
- Range: 305 – 2800 nm; impedance (nominal) 50 - 60 ohms
- Sensitivity: 7 - 17 µV/W/m2; temperature dependence of sensitivity
< ± 1% (-20 to +50°C)
- Directional error: < ± 10 W/m2(beam 1000 W/m2); tilt error: none;
Zero-offset due to temperature changes: < ± 2 W/m2 at 5 K/h temperature
change
- Dimensions W x H 150.0 mm x 91.5 mm; weight 850 grams; cable length
10 m
- Operating temperature -40°C to +80°C
Back to top
Met One Wind Sensor: 034A/B
- Wind speed range: 0 - 167 mph (0-75 m/s); accuracy < 22.7 mph:
.25 mph (0.1 m/s); accuracy > 22.7 mph: ±1.1% of true
- Wind direction mechanical range: 0-360°, electrical range: 0-356°;
accuracy: ±4°
- Mounts with PN 2954 Alignment Adapter to a vertical 1.0” tubing
or pipe (1.05” O.D.)
- Sensor Weight: 1 lb 12.5 oz (0.81 kg)
Back to top
RM Young Electrical Compass/Serial Interface: 32500
The compass module is combined with high-resolution interface circuitry
to generate useful "true" wind data from the wind sensor. Auxiliary sensor
inputs allow connection of other meteorological sensors such as temperature,
humidity and barometric pressure sensors. All analog signals are converted
to serial format for clear transmission.
- Accuracy: ±2° RMS
- Size - height: 4.75 in (12 cm); width: 2.87 in (7.3 cm); depth: 2.12
in (5.3 cm)
- Inputs - YOUNG wind sensors: 2 channels, 0-1000 mV; 2 channels, 0-5000
mV
- Outputs - Serial RS232 / RS485; selectable formats: ASCII Text, NMEA,
RMYT compatible with 06201 display.
- Power: 10 to 30 VDC, 30 mA
- Mounting: 1" IPS (1.34" actual diameter)
Back to top
RM Young Relative Humidity/Temperature Probe: 41372
The Model 41372 Relative Humidity/Temperature Probe combines a high accuracy,
capacitance type humidity sensor and 1000 ohm Platinum RTD temperature sensor
in one probe. This probe offers a choice of 0-1 VDC or 4-20 mA outputs for
T and RH.
- Relative humidity range: 0-100 %RH; accuracy at 20 °C: ±
3 % from 10 to 90 %RH, ±4 % from 0 to 10 %, & 90 to 100 %RH
- Relative humidity operating temperature: -10 to 60 °C (14 to 140 °F)
(below -10 °C, accuracy reduced); sensor type: Vaisala Intercap;
- Temperature range: -50 to 50 °C, -50 to 150 °F ; accuracy
at 0 °C: ±0.3 °C(Differential measurement recommended
with V option)
- Terperature sensor type: 1000 ohms Platinum RTD
- Power - V option: 8-24 VDC 9 mA; L option: 12-30 VDC 40 mA
Back to top
RM Young Wind Sensor: 5106MA

For offshore and marine use, the Model 05106, Wind Monitor-MA features special
waterproof bearing lubricant and a sealed, heavy-duty cable pigtail in place
of the standard junction box. Separate signal conditioning for voltage or
current outputs is available.
- Wind speed range: 0 - 60 m/s (134 mph); accuracy: ±0.3 m/s
(0.6 mph)
- Wind direction mechanical range: 0-360°, electrical range: 0-355°;
accuracy: ±3°
- Overall height: 37 cm (14.6 in); length: 55 cm (21.7 in); 18 cm (7
in) diameter; weight: 1.0 kg (2.2 lbs)
- Mounting: 34 mm (1.34 in) diameter (std. 1 inch pipe)
- Gust survival: 100 m/s (220 mph)
Back to top
Solar Radiation Sensor : Campbell
Sci LI190SB (currently not hooked up)
- Measures Photosynthetic Photon Flux Density (PPFD) in both natural
and artificial light
- Measurement waveband: 400 to 700 nm
- Uses a silicon photovoltaic detector
- Ideal for growth chambers and greenhouses
- Manufactured by Li-Cor
- Product
Literature (96 kBytes)
- Manual
(109 kBytes)
Back to top
Temperature and Relative Humidity Probe: CS500
- Uses PRT for temperature measurement; capacitive RH chip for RH
- Accuracy is ±3% over 10-90% RH; ±6% over 90-100% RH
- Sensor body is under 3" long; less than 0.5" diameter
- Radiation shield recommended when exposed to sunlight
- Based on Vaisala 50Y Sensor
- Product Literature (40 kBytes)
- Manual (270 kBytes)
- Mounting Options: 1) CM6, CM10, UT10: 41303
and 015ARM;
2) UT10, UT20, UT30: UT018 and
UT6P
Back to top
Temperature and Relative Humidity Probe: HMP45C
- Uses PRT for temperature measurement; capacitive RH chip for RH
- Accuracy is ±2% over 10-90% RH; ±3% over 90-100% RH
- Small - sensor body is under 10" long; less than 1" diameter
- Radiation shield recommended when exposed to sunlight
- Based on Vaisala HMP-series sensors
- HMP41 Sensor Head available to facilitate recalibration
- Product Literature (172 kBytes)
- Manual (216 kBytes)
- Mounting Options: 1) CM6, CM10, UT10: 41003;
2) UT10, UT20, UT30: UT12VA and
UT018
Back to top
Air Temperature: Campbell Sci 107
Temperature Probe
- Measures air, soil, or water temperature
- Incorporates a thermistor as the active element
- Recommended for -35º to +50ºC temperature range
- Naturally aspirated radiation shield recommended when exposed to sunlight
-
Product Literature (130 kBytes, PDF)
- Manual
(115 kBytes, PDF)
Back to top
Tipping Bucket (precipitation)
: Campbell Sci TE525WS
- Tips at
0.01" increments
- Orifice
diameter is 8"
- Accuracy
is ±1% at rates up to 1" hr-1
- Product
Literature (367 kBytes)
- Manual
(44 kBytes)
Back to top
Vaisala Ultrasonic Wind Sensor: WS425
With its continuous data availability, the WS425 is ideal for a variety
of wind measurement applications such as meteorology, aviation, road and
railway safety and energy production.
- Wind speed range: 0...65 m/s (0...144 mph, 0...125 knots); accuracy:
±0.135 m/s (±0.3 mph, ±0.26 knots) or 3% of reading, whichever is greater
- Wind direction range: 0...360°; accuracy: ±2°
- Measurement based on ultrasound
- Triangular shape prevents wind interference between transducer heads
- RS232/485/422, SDI-12 and analog outputs
- Power: 5Vdc, 4mA from logger
- Operates with 10...15 VDC, additional 36 VDC required for heated model
- WS425 Brochure (54 kBytes)
Back to top
Water Content (at pole and tripod):
Campbell Sci CS615 Water Content Reflectometer
- Uses time-domain
measurement methods
- Indirectly
measures soil volumetric water content via dielectric constant measurements
- Accuracy
±3% typical, ±2% with soil specific calibration
- Designed
for long-term unattended water content monitoring
- Measurement
time less than 0.1 second
- Uses datalogger
single-ended input channel or pulse channel
- Product
Literature (66 kBytes, PDF)
- Manual
(73 kBytes, PDF)
Back to top
Wind Speed and Direction: Campbell Sci 03001 Wind Sentry
Wind Set
- 3-cup anemometer and wind vane mounted on a common crossarm
- Rugged design; CSI version uses shielded rather than sealed bearings
(lowers threshold)
- Manufactured by R.M. Young
- Product
Literature (106
kByte PDF)
Back to top |